Machine technical sheet


Immagine rappresentane il macchinario
Brand: IVECO
Model: 35 A
Type: Motor vehicle for the transport of goods <35 ql (delivery van)
Built in: n.d.
Power supply: Internal combustion diesel engine
Immagine rappresentante la tipologia
Declared values as set forth in the standard NON DISPONIBILE
CONDITIONS MATERIAL K(1)
No declared data
(1) Expanded uncertainty

Measurements in the field (Click to view the measurements in the field)


Referente: CPT Cagliari ( cptcagliari@tiscali.it)
Location: Ussana - (CA)
on 2007-09-21
Ground / road type: Road: asphalt
Ground / road conditions: Road: smooth (or good condition)
Forward speed (IN ITALIAN): NON INDICATA
SEDILE
Seat type: di serie
Seat brand: NON DISPONIBILE
Seat model: NON DISPONIBILE
Seat suspension type: NON INDICATA
Potential adjustments of the seat: assente
Armrests: Assenti

Values related to the vibration worst case position: sedile
a wx (Mean):
0.2 m/s2
a wy (Mean)
0.6 m/s2
a wz (Mean)
0.6 m/s2
dev. std. x 1,645:
0.01 m/s2
dev. std. x 1,645:
0.02 m/s2
dev. std. x 1,645:
0 m/s2
Mean
+ (dev. std. x 1,645):
0.2 m/s2
Mean
+ (dev. std. x 1,645):
0.6 m/s2
Mean
+ (dev. std. x 1,645):
0.6 m/s2
x 1.4
0.3 m/s2
X 1.4
0.8 m/s2
x 1
0.6 m/s2
a wv max
0.8 m/s2

Referente: AUSL Toscana Sud Est-LSP-Lab. Agenti Fisici
Nome: Iole Pinto - Nicola Stacchini - Andrea Bogi ( i.pinto@usl7.toscana.it)
Location: Asciano (SI)
on 2014-09-25
Ground / road type: asphalt cement
Ground / road conditions: Ground: presence of potholes
Forward speed (IN ITALIAN): moderata
SEDILE
Seat type: di serie
Seat brand: NON DISPONIBILE
Seat model: NON DISPONIBILE
Seat suspension type: NON INDICATA
Potential adjustments of the seat: assente
Armrests: Presenti
Conditions of measurement
Conditions of measurement

Values related to the vibration worst case position: sedile
a wx (Mean):
0.2 m/s2
a wy (Mean)
0.2 m/s2
a wz (Mean)
0.4 m/s2
dev. std. x 1,645:
0.03 m/s2
dev. std. x 1,645:
0.01 m/s2
dev. std. x 1,645:
0.06 m/s2
Mean
+ (dev. std. x 1,645):
0.2 m/s2
Mean
+ (dev. std. x 1,645):
0.2 m/s2
Mean
+ (dev. std. x 1,645):
0.5 m/s2
x 1.4
0.3 m/s2
X 1.4
0.3 m/s2
x 1
0.5 m/s2
a wv max
0.5 m/s2
 

VDV8h

Valori relativi alla posizione peggiore: sedile
VDV wx (Mean):
4.3 m/s1.75
VDV wy (Mean)
5.8 m/s1.75
VDV wz (Mean)
8.6 m/s1.75
dev. std. x 1,645:
0.97 m/s1.75
dev. std. x 1,645:
0.12 m/s1.75
dev. std. x 1,645:
2.16 m/s1.75
Mean
+ (dev. std. x 1,645):
5.3 m/s1.75
Mean
+ (dev. std. x 1,645):
5.9 m/s1.75
Mean
+ (dev. std. x 1,645):
10.8 m/s1.75
x 1.4
7.4 m/s1.75
X 1.4
8.2 m/s1.75
x 1
10.8 m/s1.75
VDV wv 8h max
10.8 m/s1.75