Machine technical sheet


Immagine rappresentane il macchinario
Brand: IVECO
Model: 49.12 (cambio automatico)
Type: Mini city bus
Built in: n.d.
Power supply: Internal combustion diesel engine
Immagine rappresentante la tipologia
Declared values as set forth in the standard UNI ISO 2631-1:2014
CONDITIONS MATERIAL K(1)
No declared data
(1) Expanded uncertainty

Measurements in the field (Click to view the measurements in the field)


Referente: AUSL Toscana Sud Est-LSP-Lab. Agenti Fisici
Nome: Iole Pinto - Nicola Stacchini - Andrea Bogi ( i.pinto@usl7.toscana.it)
Location: Azienda TRA.IN. SpA Siena
on 2006-04-28
Ground / road type: Road: asphalt
Ground / road conditions: Road: adequate
Forward speed (IN ITALIAN): NON INDICATA
NOTES: listelli di pvc sul piano del sedile
SEDILE
Seat type: modificato
Seat brand: NON DISPONIBILE
Seat model: NON DISPONIBILE
Seat suspension type: Meccanica
Potential adjustments of the seat: peso
Armrests: Assenti
Conditions of measurement

Values related to the vibration worst case position: sedile
a wx (Mean):
0.1 m/s2
a wy (Mean)
0.1 m/s2
a wz (Mean)
0.2 m/s2
dev. std. x 1,645:
0.01 m/s2
dev. std. x 1,645:
0.02 m/s2
dev. std. x 1,645:
0.03 m/s2
Mean
+ (dev. std. x 1,645):
0.1 m/s2
Mean
+ (dev. std. x 1,645):
0.1 m/s2
Mean
+ (dev. std. x 1,645):
0.3 m/s2
x 1.4
0.1 m/s2
X 1.4
0.1 m/s2
x 1
0.3 m/s2
a wv max
0.3 m/s2

Referente: AUSL Toscana Sud Est-LSP-Lab. Agenti Fisici
Nome: Iole Pinto - Nicola Stacchini - Andrea Bogi ( i.pinto@usl7.toscana.it)
Location: Azienda TRA.IN. SpA Siena
on 2006-04-27
Ground / road type: Road: paved road
Ground / road conditions: Ground: presence of potholes
Forward speed (IN ITALIAN): NON INDICATA
NOTES: listelli di pvc sul piano del sedile
SEDILE
Seat type: modificato
Seat brand: NON DISPONIBILE
Seat model: NON DISPONIBILE
Seat suspension type: Meccanica
Potential adjustments of the seat: peso
Armrests: Assenti
Conditions of measurement

Values related to the vibration worst case position: sedile
a wx (Mean):
0.1 m/s2
a wy (Mean)
0.1 m/s2
a wz (Mean)
0.3 m/s2
dev. std. x 1,645:
0.01 m/s2
dev. std. x 1,645:
0.02 m/s2
dev. std. x 1,645:
0.06 m/s2
Mean
+ (dev. std. x 1,645):
0.1 m/s2
Mean
+ (dev. std. x 1,645):
0.1 m/s2
Mean
+ (dev. std. x 1,645):
0.4 m/s2
x 1.4
0.2 m/s2
X 1.4
0.2 m/s2
x 1
0.4 m/s2
a wv max
0.4 m/s2

Referente: AUSL Toscana Sud Est-LSP-Lab. Agenti Fisici
Nome: Iole Pinto - Nicola Stacchini - Andrea Bogi ( i.pinto@usl7.toscana.it)
Location: Azienda TRA.IN. SpA Siena
on 2006-04-27
Ground / road type: Road: asphalt
Ground / road conditions: Road: adequate
Forward speed (IN ITALIAN): NON INDICATA
NOTES: listelli di pvc sul piano del sedile
SEDILE
Seat type: modificato
Seat brand: NON DISPONIBILE
Seat model: NON DISPONIBILE
Seat suspension type: Meccanica
Potential adjustments of the seat: peso
Armrests: Assenti
Conditions of measurement

Values related to the vibration worst case position: sedile
a wx (Mean):
0.1 m/s2
a wy (Mean)
0.1 m/s2
a wz (Mean)
0.2 m/s2
dev. std. x 1,645:
0.01 m/s2
dev. std. x 1,645:
0.02 m/s2
dev. std. x 1,645:
0.05 m/s2
Mean
+ (dev. std. x 1,645):
0.1 m/s2
Mean
+ (dev. std. x 1,645):
0.1 m/s2
Mean
+ (dev. std. x 1,645):
0.3 m/s2
x 1.4
0.1 m/s2
X 1.4
0.1 m/s2
x 1
0.3 m/s2
a wv max
0.3 m/s2

Referente: AUSL Toscana Sud Est-LSP-Lab. Agenti Fisici
Nome: Iole Pinto - Nicola Stacchini - Andrea Bogi ( i.pinto@usl7.toscana.it)
Location: Siena - Azienda Trasporti pubblici
on 1998-01-01
Ground / road type: Road: asphalt
Ground / road conditions: NOT ASSESSED
Forward speed (IN ITALIAN): NON INDICATA
NOTES: Note: matricola mezzo 1016 LEQ:76
SEDILE
Seat type: di serie
Seat brand: NON DISPONIBILE
Seat model: NON DISPONIBILE
Seat suspension type: Meccanica
Potential adjustments of the seat: peso
Armrests: Assenti

Values related to the vibration worst case position: sedile
a wx (Mean):
0.1 m/s2
a wy (Mean)
0 m/s2
a wz (Mean)
0.5 m/s2
dev. std. x 1,645:
0.16 m/s2
dev. std. x 1,645:
0.16 m/s2
dev. std. x 1,645:
0.16 m/s2
Mean
+ (dev. std. x 1,645):
0.2 m/s2
Mean
+ (dev. std. x 1,645):
0.2 m/s2
Mean
+ (dev. std. x 1,645):
0.6 m/s2
x 1.4
0.3 m/s2
X 1.4
0.2 m/s2
x 1
0.6 m/s2
a wv max
0.6 m/s2

Referente: AUSL Toscana Sud Est-LSP-Lab. Agenti Fisici
Nome: Iole Pinto - Nicola Stacchini - Andrea Bogi ( i.pinto@usl7.toscana.it)
Location: Siena - Azienda Trasporti pubblici
on 1998-01-01
Ground / road type: Road: paved road
Ground / road conditions: NOT ASSESSED
Forward speed (IN ITALIAN): NON INDICATA
NOTES: Note: matricola mezzo 1016 LEQ:75
SEDILE
Seat type: di serie
Seat brand: NON DISPONIBILE
Seat model: NON DISPONIBILE
Seat suspension type: Meccanica
Potential adjustments of the seat: peso
Armrests: Assenti

Values related to the vibration worst case position: sedile
a wx (Mean):
0.1 m/s2
a wy (Mean)
0.2 m/s2
a wz (Mean)
0.5 m/s2
dev. std. x 1,645:
0.16 m/s2
dev. std. x 1,645:
0.16 m/s2
dev. std. x 1,645:
0.16 m/s2
Mean
+ (dev. std. x 1,645):
0.3 m/s2
Mean
+ (dev. std. x 1,645):
0.3 m/s2
Mean
+ (dev. std. x 1,645):
0.7 m/s2
x 1.4
0.4 m/s2
X 1.4
0.5 m/s2
x 1
0.7 m/s2
a wv max
0.7 m/s2

Referente: AUSL Toscana Sud Est-LSP-Lab. Agenti Fisici
Nome: Iole Pinto - Nicola Stacchini - Andrea Bogi ( i.pinto@usl7.toscana.it)
Location: Azienda TRA.IN. SpA Siena
on 2006-04-28
Ground / road type: Road: paved road
Ground / road conditions: Ground: presence of potholes
Forward speed (IN ITALIAN): NON INDICATA
NOTES: listelli di pvc sul piano del sedile
SEDILE
Seat type: modificato
Seat brand: NON DISPONIBILE
Seat model: NON DISPONIBILE
Seat suspension type: Meccanica
Potential adjustments of the seat: peso
Armrests: Assenti
Conditions of measurement

Values related to the vibration worst case position: sedile
a wx (Mean):
0.1 m/s2
a wy (Mean)
0.1 m/s2
a wz (Mean)
0.3 m/s2
dev. std. x 1,645:
0.01 m/s2
dev. std. x 1,645:
0.01 m/s2
dev. std. x 1,645:
0.02 m/s2
Mean
+ (dev. std. x 1,645):
0.1 m/s2
Mean
+ (dev. std. x 1,645):
0.2 m/s2
Mean
+ (dev. std. x 1,645):
0.4 m/s2
x 1.4
0.2 m/s2
X 1.4
0.2 m/s2
x 1
0.4 m/s2
a wv max
0.4 m/s2
logo regione toscana
Regione Toscana
Diritti Valori Innovazione Sostenibilità
collegamento sito usl 7 siena Servizio Sanitario
della
Toscana
LOADING TIME: 0.026 s.
XS SM MD LG XL

info@portaleagentifisici.it