Machine technical sheet


Brand: ATLAS COPCO
Model: C 148
Type: Demolition hammers (light demolitions), road breakers and pick hammers (for rocks, buildings etc)
Built in: n.d.
Power supply: Internal combustion gasoline engine
Anti-vibration devices: Absent
Source of the data: Acquisito sul campo da misuratore

Immagine rappresentante la tipologia
Declared values as set forth in the standard EN 50144-2-6
( x 2,0 Hammer drilling, Chiseling, Drilling without impact - x 1,5 Breaking concrete/masonry )
CONDITIONS MATERIAL ACCESSORY VALUE K(1) Note
No declared data
(1) Expanded uncertainty

Measurements in the field (Click to view the measurements in the field)

Reference person: Pietro Nataletti ISPESL INAIL (p.nataletti@inail.it)
Location: Trento e Provincia on null
Features of the accessory: Pick, moil point
domDebug Array ( [id] => 642 [data] => [referente] => 6 [dichiarazione_di_pubblicabilita] => [luogo] => Trento e Provincia [comparto] => Costruzioni stradali e ferroviarie [numero_di_serie] => [accessorio_usato] => 1057 [t_lavoro_effettuato] => 7 [materiale_lavorato] => 203 [leq] => [note] => [foto1] => [foto2] => [foto3] => [pressione] => [frequenza] => [isValid] => Yes [referente2] => 6 [caratteristicheAccessorio] => punta esagonale tagliata 32mm [durata] => [en_luogo] => [importato] => Yes [caratteristicheLavoroEffettuato] => perforazione [caratteristicheMateriale] => calcare [en_note] => [id_anagrafica_generale] => 946 [owner_user] => 0 [stato] => [id_modello_strumento_di_misura] => 0 [id_sensore_strumento_di_misura] => 0 [id_adattatore_del_sensore] => 0 [accessorio] => Punta piramidale, punta conica [en_accessorio] => Pick, moil point [materiale] => Pietra [en_materiale] => Stone [denominazione] => ISPESL INAIL [nome_cognome] => Pietro Nataletti [tel] => 06 94181421 [email] => p.nataletti@inail.it [username] => nataletti [categoria] => 2 [lavoro] => Foratura [en_lavoro] => Drilling [en_comparto] => Construction of roads and railways )

Values related to the vibration worst case handle ​ ( Left )
A hx (Mean)
5.8 m/s2
A hy (Mean)
11.3 m/s2
A hz (Mean)
22.4 m/s2
A hv sum
25.8 m/s2
Standard deviation
0.1 m/s2
Standard deviation
0.1 m/s2
Standard deviation
0.1 m/s2
Standard deviation x 1,645:
0.16 m/s2
Mean
+ Standard deviation:
5.9 m/s2
Mean
+ Standard deviation:
11.4 m/s2
Mean
+ Standard deviation:
22.5 m/s2
A hv sum
+ (Dev. std. x 1,645):
26 m/s2