Machine technical sheet


Brand: MAKITA
Model: HR 4001C
Type: Rock drills and rotary hammers
Built in: n.d.
Weight: 6.3 kg
Power: 1.1 kW
Power supply: Electrical (220V-380V)
Anti-vibration devices: Absent
Last update: 17/09/2015
Source of the data: Acquisito sul campo da misuratore

Immagine rappresentante la tipologia
Declared values as set forth in the standard IEC EN 60745-2-6:2003
CONDITIONS MATERIAL ACCESSORY VALUE K(1) Note
DrillingConcretePick, moil point12.5 m/s21.5Hammer drilling into concrete
ChiselingConcreteChisel10.5 m/s22Chiselling
NOT ASSESSEDNOT ASSESSEDNOT ASSESSED10 m/s22.5Chiselling function with side grip
(1) Expanded uncertainty

Measurements in the field (Click to view the measurements in the field)

Reference person: CPT Torino (seg@cpt.to.it)
Location: TRANA (TO) on 04/12/2006
Features of the accessory: NOT ASSESSED
domDebug Array ( [id] => 481 [data] => 2006-12-04 [referente] => 14 [dichiarazione_di_pubblicabilita] => [luogo] => TRANA (TO) [comparto] => Costruzioni edili [numero_di_serie] => [accessorio_usato] => 1045 [t_lavoro_effettuato] => 6 [materiale_lavorato] => 191 [leq] => 0 [note] => scheda 116 [foto1] => [foto2] => [foto3] => [pressione] => [frequenza] => [isValid] => Yes [referente2] => 14 [caratteristicheAccessorio] => [durata] => [en_luogo] => [importato] => Yes [caratteristicheLavoroEffettuato] => demolizione cordolo [caratteristicheMateriale] => cemento [en_note] => [id_anagrafica_generale] => 602 [owner_user] => 0 [stato] => [id_modello_strumento_di_misura] => 0 [id_sensore_strumento_di_misura] => 0 [id_adattatore_del_sensore] => 0 [accessorio] => NON INDICATO [en_accessorio] => NOT ASSESSED [materiale] => Calcestruzzo [en_materiale] => Concrete [denominazione] => CPT Torino [nome_cognome] => [tel] => 0113400311 [email] => seg@cpt.to.it [username] => cpttorino [categoria] => 2 [lavoro] => Demolizione [en_lavoro] => Demolition [en_comparto] => Building constructions )

Values related to the vibration worst case handle ​ ( Posterior )
A hx (Mean)
13.9 m/s2
A hy (Mean)
6.7 m/s2
A hz (Mean)
11.9 m/s2
A hv sum
19.5 m/s2
Standard deviation
0.71 m/s2
Standard deviation
0.44 m/s2
Standard deviation
0.46 m/s2
Standard deviation x 1,645:
1.29 m/s2
Mean
+ Standard deviation:
14.6 m/s2
Mean
+ Standard deviation:
7.1 m/s2
Mean
+ Standard deviation:
12.4 m/s2
A hv sum
+ (Dev. std. x 1,645):
20.8 m/s2
Reference person: CPT Torino (seg@cpt.to.it)
Location: TORINO (TO) on 11/12/2006
Features of the accessory: Pick, moil point
domDebug Array ( [id] => 467 [data] => 2006-12-11 [referente] => 14 [dichiarazione_di_pubblicabilita] => [luogo] => TORINO (TO) [comparto] => Costruzioni edili [numero_di_serie] => [accessorio_usato] => 1057 [t_lavoro_effettuato] => 6 [materiale_lavorato] => 191 [leq] => 0 [note] => scheda 130 [foto1] => [foto2] => [foto3] => [pressione] => [frequenza] => [isValid] => Yes [referente2] => 14 [caratteristicheAccessorio] => punta da demolizione [durata] => [en_luogo] => [importato] => Yes [caratteristicheLavoroEffettuato] => demolizione muro [caratteristicheMateriale] => c.a. [en_note] => [id_anagrafica_generale] => 602 [owner_user] => 0 [stato] => [id_modello_strumento_di_misura] => 0 [id_sensore_strumento_di_misura] => 0 [id_adattatore_del_sensore] => 0 [accessorio] => Punta piramidale, punta conica [en_accessorio] => Pick, moil point [materiale] => Calcestruzzo [en_materiale] => Concrete [denominazione] => CPT Torino [nome_cognome] => [tel] => 0113400311 [email] => seg@cpt.to.it [username] => cpttorino [categoria] => 2 [lavoro] => Demolizione [en_lavoro] => Demolition [en_comparto] => Building constructions )

Values related to the vibration worst case handle ​ ( Posterior )
A hx (Mean)
8.5 m/s2
A hy (Mean)
6.9 m/s2
A hz (Mean)
7.3 m/s2
A hv sum
13.1 m/s2
Standard deviation
0.78 m/s2
Standard deviation
0.84 m/s2
Standard deviation
0.37 m/s2
Standard deviation x 1,645:
1.28 m/s2
Mean
+ Standard deviation:
9.3 m/s2
Mean
+ Standard deviation:
7.7 m/s2
Mean
+ Standard deviation:
7.7 m/s2
A hv sum
+ (Dev. std. x 1,645):
14.4 m/s2
Reference person: CPT Perugia (info@cptperugia.it)
Location: GUBBIO (PG) on 30/05/2007
Features of the accessory: Pick, moil point
domDebug Array ( [id] => 293 [data] => 2007-05-30 [referente] => 12 [dichiarazione_di_pubblicabilita] => [luogo] => GUBBIO (PG) [comparto] => Costruzioni edili [numero_di_serie] => [accessorio_usato] => 1057 [t_lavoro_effettuato] => 6 [materiale_lavorato] => 203 [leq] => 0 [note] => [foto1] => [foto2] => [foto3] => [pressione] => [frequenza] => [isValid] => Yes [referente2] => 12 [caratteristicheAccessorio] => PUNTA [durata] => [en_luogo] => [importato] => Yes [caratteristicheLavoroEffettuato] => DEMOLIZIONE [caratteristicheMateriale] => PIETRA [en_note] => [id_anagrafica_generale] => 602 [owner_user] => 0 [stato] => [id_modello_strumento_di_misura] => 0 [id_sensore_strumento_di_misura] => 0 [id_adattatore_del_sensore] => 0 [accessorio] => Punta piramidale, punta conica [en_accessorio] => Pick, moil point [materiale] => Pietra [en_materiale] => Stone [denominazione] => CPT Perugia [nome_cognome] => [tel] => 0755059411 [email] => info@cptperugia.it [username] => cptperugia [categoria] => 2 [lavoro] => Demolizione [en_lavoro] => Demolition [en_comparto] => Building constructions )

Values related to the vibration worst case handle ​ ( Right )
A hx (Mean)
13.1 m/s2
A hy (Mean)
9.1 m/s2
A hz (Mean)
6.1 m/s2
A hv sum
17 m/s2
Standard deviation
4.16 m/s2
Standard deviation
0.5 m/s2
Standard deviation
1.02 m/s2
Standard deviation x 1,645:
5.37 m/s2
Mean
+ Standard deviation:
17.3 m/s2
Mean
+ Standard deviation:
9.6 m/s2
Mean
+ Standard deviation:
7.1 m/s2
A hv sum
+ (Dev. std. x 1,645):
22.4 m/s2
Reference person: CPT Cagliari (cptcagliari@tiscali.it)
Location: Cagliari on 17/04/2007
Features of the accessory: Chisel
domDebug Array ( [id] => 253 [data] => 2007-04-17 [referente] => 11 [dichiarazione_di_pubblicabilita] => [luogo] => Cagliari [comparto] => Costruzioni edili [numero_di_serie] => [accessorio_usato] => 1058 [t_lavoro_effettuato] => 6 [materiale_lavorato] => 191 [leq] => [note] => [foto1] => [foto2] => [foto3] => [pressione] => [frequenza] => [isValid] => Yes [referente2] => 11 [caratteristicheAccessorio] => Scalpello [durata] => [en_luogo] => [importato] => Yes [caratteristicheLavoroEffettuato] => Demolizione [caratteristicheMateriale] => Calcestruzzo [en_note] => [id_anagrafica_generale] => 602 [owner_user] => 0 [stato] => [id_modello_strumento_di_misura] => 0 [id_sensore_strumento_di_misura] => 0 [id_adattatore_del_sensore] => 0 [accessorio] => Scalpello [en_accessorio] => Chisel [materiale] => Calcestruzzo [en_materiale] => Concrete [denominazione] => CPT Cagliari [nome_cognome] => [tel] => 0702084120 [email] => cptcagliari@tiscali.it [username] => cptcagliari [categoria] => 2 [lavoro] => Demolizione [en_lavoro] => Demolition [en_comparto] => Building constructions )

Values related to the vibration worst case handle ​ ( Posterior )
A hx (Mean)
19.4 m/s2
A hy (Mean)
5.3 m/s2
A hz (Mean)
11.9 m/s2
A hv sum
23.4 m/s2
Standard deviation
0.16 m/s2
Standard deviation
0.16 m/s2
Standard deviation
0.1 m/s2
Standard deviation x 1,645:
0.33 m/s2
Mean
+ Standard deviation:
19.6 m/s2
Mean
+ Standard deviation:
5.5 m/s2
Mean
+ Standard deviation:
12 m/s2
A hv sum
+ (Dev. std. x 1,645):
23.7 m/s2
Reference person: CPT Cagliari (cptcagliari@tiscali.it)
Location: Cagliari on 17/04/2007
Features of the accessory: Chisel
domDebug Array ( [id] => 245 [data] => 2007-04-17 [referente] => 11 [dichiarazione_di_pubblicabilita] => [luogo] => Cagliari [comparto] => Costruzioni edili [numero_di_serie] => [accessorio_usato] => 1058 [t_lavoro_effettuato] => 6 [materiale_lavorato] => 191 [leq] => [note] => [foto1] => Yes [foto2] => [foto3] => [pressione] => [frequenza] => [isValid] => Yes [referente2] => 11 [caratteristicheAccessorio] => Scalpello [durata] => [en_luogo] => [importato] => Yes [caratteristicheLavoroEffettuato] => Demolizione [caratteristicheMateriale] => Calcestruzzo [en_note] => [id_anagrafica_generale] => 602 [owner_user] => 0 [stato] => [id_modello_strumento_di_misura] => 0 [id_sensore_strumento_di_misura] => 0 [id_adattatore_del_sensore] => 0 [accessorio] => Scalpello [en_accessorio] => Chisel [materiale] => Calcestruzzo [en_materiale] => Concrete [denominazione] => CPT Cagliari [nome_cognome] => [tel] => 0702084120 [email] => cptcagliari@tiscali.it [username] => cptcagliari [categoria] => 2 [lavoro] => Demolizione [en_lavoro] => Demolition [en_comparto] => Building constructions )
Conditions of measurement

Values related to the vibration worst case handle ​ ( Posterior )
A hx (Mean)
5.9 m/s2
A hy (Mean)
3.9 m/s2
A hz (Mean)
5.4 m/s2
A hv sum
8.9 m/s2
Standard deviation
0.11 m/s2
Standard deviation
0.02 m/s2
Standard deviation
0.08 m/s2
Standard deviation x 1,645:
0.16 m/s2
Mean
+ Standard deviation:
6 m/s2
Mean
+ Standard deviation:
3.9 m/s2
Mean
+ Standard deviation:
5.5 m/s2
A hv sum
+ (Dev. std. x 1,645):
9.1 m/s2
Reference person: CPT Torino (seg@cpt.to.it)
Location: TORINO (TO) on 11/12/2006
Features of the accessory: Pick, moil point
domDebug Array ( [id] => 468 [data] => 2006-12-11 [referente] => 14 [dichiarazione_di_pubblicabilita] => [luogo] => TORINO (TO) [comparto] => Costruzioni edili [numero_di_serie] => [accessorio_usato] => 1057 [t_lavoro_effettuato] => 7 [materiale_lavorato] => 191 [leq] => 0 [note] => scheda 130 [foto1] => [foto2] => [foto3] => [pressione] => [frequenza] => [isValid] => Yes [referente2] => 14 [caratteristicheAccessorio] => punta elicoidale (diametro 20 mm) [durata] => [en_luogo] => [importato] => Yes [caratteristicheLavoroEffettuato] => foratura muro [caratteristicheMateriale] => c.a. [en_note] => [id_anagrafica_generale] => 602 [owner_user] => 0 [stato] => [id_modello_strumento_di_misura] => 0 [id_sensore_strumento_di_misura] => 0 [id_adattatore_del_sensore] => 0 [accessorio] => Punta piramidale, punta conica [en_accessorio] => Pick, moil point [materiale] => Calcestruzzo [en_materiale] => Concrete [denominazione] => CPT Torino [nome_cognome] => [tel] => 0113400311 [email] => seg@cpt.to.it [username] => cpttorino [categoria] => 2 [lavoro] => Foratura [en_lavoro] => Drilling [en_comparto] => Building constructions )

Values related to the vibration worst case handle ​ ( Anterior )
A hx (Mean)
6.9 m/s2
A hy (Mean)
3.5 m/s2
A hz (Mean)
4.5 m/s2
A hv sum
9 m/s2
Standard deviation
2.56 m/s2
Standard deviation
0.42 m/s2
Standard deviation
0.51 m/s2
Standard deviation x 1,645:
3.75 m/s2
Mean
+ Standard deviation:
9.5 m/s2
Mean
+ Standard deviation:
3.9 m/s2
Mean
+ Standard deviation:
5 m/s2
A hv sum
+ (Dev. std. x 1,645):
12.8 m/s2
Reference person: CPT Cagliari (cptcagliari@tiscali.it)
Location: Cagliari on 17/04/2007
Features of the accessory: Pick, moil point
domDebug Array ( [id] => 254 [data] => 2007-04-17 [referente] => 11 [dichiarazione_di_pubblicabilita] => [luogo] => Cagliari [comparto] => Costruzioni edili [numero_di_serie] => [accessorio_usato] => 1057 [t_lavoro_effettuato] => 7 [materiale_lavorato] => 191 [leq] => [note] => [foto1] => [foto2] => [foto3] => [pressione] => [frequenza] => [isValid] => Yes [referente2] => 11 [caratteristicheAccessorio] => Punta da 16 mm [durata] => [en_luogo] => [importato] => Yes [caratteristicheLavoroEffettuato] => Perforazione [caratteristicheMateriale] => Calcestruzzo [en_note] => [id_anagrafica_generale] => 602 [owner_user] => 0 [stato] => [id_modello_strumento_di_misura] => 0 [id_sensore_strumento_di_misura] => 0 [id_adattatore_del_sensore] => 0 [accessorio] => Punta piramidale, punta conica [en_accessorio] => Pick, moil point [materiale] => Calcestruzzo [en_materiale] => Concrete [denominazione] => CPT Cagliari [nome_cognome] => [tel] => 0702084120 [email] => cptcagliari@tiscali.it [username] => cptcagliari [categoria] => 2 [lavoro] => Foratura [en_lavoro] => Drilling [en_comparto] => Building constructions )

Values related to the vibration worst case handle ​ ( Anterior )
A hx (Mean)
12.6 m/s2
A hy (Mean)
4.3 m/s2
A hz (Mean)
7 m/s2
A hv sum
15 m/s2
Standard deviation
0.14 m/s2
Standard deviation
0.1 m/s2
Standard deviation
0.06 m/s2
Standard deviation x 1,645:
0.25 m/s2
Mean
+ Standard deviation:
12.7 m/s2
Mean
+ Standard deviation:
4.4 m/s2
Mean
+ Standard deviation:
7.1 m/s2
A hv sum
+ (Dev. std. x 1,645):
15.3 m/s2
logo regione toscana
Regione Toscana
Diritti Valori Innovazione Sostenibilità
collegamento sito usl 7 siena Servizio Sanitario
della
Toscana
LOADING TIME: 0.045 s.
XS SM MD LG XL

info@portaleagentifisici.it