Machine technical sheet


Brand: AEG
Model: ERGOMAX
Type: Impact drills and heavy duty drills
Built in: n.d.
Power supply: Electrical (220V-380V)
Anti-vibration devices: Absent
Source of the data: Acquisito sul campo da misuratore

Immagine rappresentante la tipologia
Declared values as set forth in the standard EN 50144-2-1
( x 1,0 Fastening screws, Impact drilling - x 1,5 Drilling with or without impulse (impact) )
CONDITIONS MATERIAL ACCESSORY VALUE K(1) Note
No declared data
(1) Expanded uncertainty

Measurements in the field (Click to view the measurements in the field)

Reference person: CPT Perugia (info@cptperugia.it)
Location: TODI (PG) on 05/04/2007
Features of the accessory: Pick, moil point
domDebug Array ( [id] => 354 [data] => 2007-04-05 [referente] => 12 [dichiarazione_di_pubblicabilita] => [luogo] => TODI (PG) [comparto] => Costruzioni edili [numero_di_serie] => [accessorio_usato] => 1057 [t_lavoro_effettuato] => 7 [materiale_lavorato] => 196 [leq] => [note] => [foto1] => [foto2] => [foto3] => [pressione] => [frequenza] => [isValid] => Yes [referente2] => 12 [caratteristicheAccessorio] => PUNTA DA 8mm [durata] => [en_luogo] => [importato] => Yes [caratteristicheLavoroEffettuato] => FORATURA [caratteristicheMateriale] => LEGNO [en_note] => [id_anagrafica_generale] => 557 [owner_user] => 0 [stato] => [id_modello_strumento_di_misura] => 0 [id_sensore_strumento_di_misura] => 0 [id_adattatore_del_sensore] => 0 [accessorio] => Punta piramidale, punta conica [en_accessorio] => Pick, moil point [materiale] => Legno [en_materiale] => Wood [denominazione] => CPT Perugia [nome_cognome] => [tel] => 0755059411 [email] => info@cptperugia.it [username] => cptperugia [categoria] => 2 [lavoro] => Foratura [en_lavoro] => Drilling [en_comparto] => Building constructions )

Values related to the vibration worst case handle ​ ( Right )
A hx (Mean)
1.2 m/s2
A hy (Mean)
1 m/s2
A hz (Mean)
0.9 m/s2
A hv sum
1.8 m/s2
Standard deviation
0.11 m/s2
Standard deviation
0.11 m/s2
Standard deviation
0.05 m/s2
Standard deviation x 1,645:
0.18 m/s2
Mean
+ Standard deviation:
1.3 m/s2
Mean
+ Standard deviation:
1.1 m/s2
Mean
+ Standard deviation:
1 m/s2
A hv sum
+ (Dev. std. x 1,645):
2 m/s2