Machine technical sheet


Brand: SPIT
Model: 352
Type: Rock drills and rotary hammers
Built in: 2004
Weight: 5.9 kg
Power: 1.1 kW
Power supply: Electrical (220V-380V)
Anti-vibration devices: Absent
Source of the data: Acquisito sul campo da misuratore

Immagine rappresentante la tipologia
Declared values as set forth in the standard EN 50144-2-6
( x 2,0 Hammer drilling, Chiseling, Drilling without impact - x 1,5 Breaking concrete/masonry )
CONDITIONS MATERIAL ACCESSORY VALUE K(1) Note
NOT ASSESSEDNOT ASSESSEDNOT ASSESSED8.8 m/s2
(1) Expanded uncertainty

Measurements in the field (Click to view the measurements in the field)

Reference person: CPT Perugia (info@cptperugia.it)
Location: TORGIANO (PG) on 27/07/2007
Features of the accessory: Chisel
domDebug Array ( [id] => 401 [data] => 2007-07-27 [referente] => 12 [dichiarazione_di_pubblicabilita] => [luogo] => TORGIANO (PG) [comparto] => Costruzioni edili [numero_di_serie] => [accessorio_usato] => 1058 [t_lavoro_effettuato] => 6 [materiale_lavorato] => 191 [leq] => 0 [note] => [foto1] => [foto2] => [foto3] => [pressione] => [frequenza] => [isValid] => Yes [referente2] => 12 [caratteristicheAccessorio] => SCALPELLO [durata] => [en_luogo] => [importato] => Yes [caratteristicheLavoroEffettuato] => DEMOLIZIONE [caratteristicheMateriale] => CLS [en_note] => [id_anagrafica_generale] => 416 [owner_user] => 0 [stato] => [id_modello_strumento_di_misura] => 0 [id_sensore_strumento_di_misura] => 0 [id_adattatore_del_sensore] => 0 [accessorio] => Scalpello [en_accessorio] => Chisel [materiale] => Calcestruzzo [en_materiale] => Concrete [denominazione] => CPT Perugia [nome_cognome] => [tel] => 0755059411 [email] => info@cptperugia.it [username] => cptperugia [categoria] => 2 [lavoro] => Demolizione [en_lavoro] => Demolition [en_comparto] => Building constructions )

Values related to the vibration worst case handle ​ ( Right )
A hx (Mean)
8.9 m/s2
A hy (Mean)
7 m/s2
A hz (Mean)
4.3 m/s2
A hv sum
12.1 m/s2
Standard deviation
0.99 m/s2
Standard deviation
0.13 m/s2
Standard deviation
0.5 m/s2
Standard deviation x 1,645:
1.17 m/s2
Mean
+ Standard deviation:
9.9 m/s2
Mean
+ Standard deviation:
7.1 m/s2
Mean
+ Standard deviation:
4.8 m/s2
A hv sum
+ (Dev. std. x 1,645):
13.3 m/s2
logo regione toscana
Regione Toscana
Diritti Valori Innovazione Sostenibilità
collegamento sito usl 7 siena Servizio Sanitario
della
Toscana
LOADING TIME: 0.028 s.