Machine technical sheet


Brand: DE WALT
Model: D25941
Type: Demolition hammers (light demolitions), road breakers and pick hammers (for rocks, buildings etc)
Built in: n.d.
Weight: 13.1 kg
Power: 1.6 kW
Power supply: Electrical (220V-380V)
Anti-vibration devices: Present
NOTES: Demolition hammer
Last update: 01/10/2014
Source of the data: www.hae.org.uk

Immagine rappresentante la tipologia
Declared values as set forth in the standard EN 60745
CONDITIONS MATERIAL ACCESSORY VALUE K(1) Note
NOT ASSESSEDNOT ASSESSEDNOT ASSESSED9 m/s21.5Chiselling on loading device (ball absorber)
(1) Expanded uncertainty

Measurements in the field (Click to view the measurements in the field)

Reference person: Giacomo Rucci ASUR Marche PSAL (giacomo.rucci@sanita.marche.it)
Location: ANCONA on 12/05/2018
Features of the accessory: Pick, moil point
domDebug Array ( [id] => 1372 [data] => 2018-05-12 [referente] => 130 [dichiarazione_di_pubblicabilita] => No [luogo] => ANCONA [comparto] => Costruzioni edili [numero_di_serie] => [accessorio_usato] => 1057 [t_lavoro_effettuato] => 6 [materiale_lavorato] => 217 [leq] => [note] => [foto1] => Yes [foto2] => No [foto3] => Yes [pressione] => [frequenza] => 1620 [isValid] => Yes [referente2] => 130 [caratteristicheAccessorio] => [durata] => 120 [en_luogo] => [importato] => [caratteristicheLavoroEffettuato] => Lavoro non continuativo [caratteristicheMateriale] => Asfalto in buono stato [en_note] => [id_anagrafica_generale] => 27370 [owner_user] => 130 [stato] => valida [id_modello_strumento_di_misura] => 2 [id_sensore_strumento_di_misura] => 58 [id_adattatore_del_sensore] => 8 [accessorio] => Punta piramidale, punta conica [en_accessorio] => Pick, moil point [materiale] => Bitume, asfalto [en_materiale] => Tarmac [denominazione] => ASUR Marche PSAL [nome_cognome] => Giacomo Rucci [tel] => 071.870 5913 [email] => giacomo.rucci@sanita.marche.it [username] => rucci [categoria] => 2 [lavoro] => Demolizione [en_lavoro] => Demolition [en_comparto] => Building constructions )
Conditions of measurement
Accelerometer mounting

Values related to the vibration worst case handle ​ ( Posterior )
A hx (Mean)
4.9 m/s2
A hy (Mean)
3.3 m/s2
A hz (Mean)
4.6 m/s2
A hv sum
7.5 m/s2
Standard deviation
0.16 m/s2
Standard deviation
0.43 m/s2
Standard deviation
0.23 m/s2
Standard deviation x 1,645:
0.69 m/s2
Mean
+ Standard deviation:
5.1 m/s2
Mean
+ Standard deviation:
3.7 m/s2
Mean
+ Standard deviation:
4.8 m/s2
A hv sum
+ (Dev. std. x 1,645):
8.2 m/s2