Machine technical sheet


Brand: BOSCH
Model: GBH 4 DFE
Type: Rock drills and rotary hammers
Built in: n.d.
Weight: 3.9 kg
Power: 0.75 kW
Power supply: Electrical (220V-380V)
Anti-vibration devices: Absent
NOTES: Rubber handle
Source of the data: Acquisito sul campo da misuratore

Immagine rappresentante la tipologia
Declared values as set forth in the standard EN 50144-2-6
( x 2,0 Hammer drilling, Chiseling, Drilling without impact - x 1,5 Breaking concrete/masonry )
CONDITIONS MATERIAL ACCESSORY VALUE K(1) Note
NOT ASSESSEDNOT ASSESSEDNOT ASSESSED11 m/s2
(1) Expanded uncertainty

Measurements in the field (Click to view the measurements in the field)

Reference person: CPT Perugia (info@cptperugia.it)
Location: SPOLETO (PG) on 13/06/2007
Features of the accessory: Pick, moil point
domDebug Array ( [id] => 301 [data] => 2007-06-13 [referente] => 12 [dichiarazione_di_pubblicabilita] => [luogo] => SPOLETO (PG) [comparto] => Costruzioni edili [numero_di_serie] => [accessorio_usato] => 1057 [t_lavoro_effettuato] => 6 [materiale_lavorato] => 191 [leq] => 0 [note] => [foto1] => [foto2] => [foto3] => [pressione] => [frequenza] => [isValid] => Yes [referente2] => 12 [caratteristicheAccessorio] => PUNTA [durata] => [en_luogo] => [importato] => Yes [caratteristicheLavoroEffettuato] => DEMOLIZIONE CLS [caratteristicheMateriale] => CLS [en_note] => [id_anagrafica_generale] => 221 [owner_user] => 0 [stato] => [id_modello_strumento_di_misura] => 0 [id_sensore_strumento_di_misura] => 0 [id_adattatore_del_sensore] => 0 [accessorio] => Punta piramidale, punta conica [en_accessorio] => Pick, moil point [materiale] => Calcestruzzo [en_materiale] => Concrete [denominazione] => CPT Perugia [nome_cognome] => [tel] => 0755059411 [email] => info@cptperugia.it [username] => cptperugia [categoria] => 2 [lavoro] => Demolizione [en_lavoro] => Demolition [en_comparto] => Building constructions )

Values related to the vibration worst case handle ​ ( Left )
A hx (Mean)
6.3 m/s2
A hy (Mean)
3.6 m/s2
A hz (Mean)
5.6 m/s2
A hv sum
9.1 m/s2
Standard deviation
0.52 m/s2
Standard deviation
0.29 m/s2
Standard deviation
0.52 m/s2
Standard deviation x 1,645:
1.21 m/s2
Mean
+ Standard deviation:
6.8 m/s2
Mean
+ Standard deviation:
3.9 m/s2
Mean
+ Standard deviation:
6.1 m/s2
A hv sum
+ (Dev. std. x 1,645):
10.3 m/s2
logo regione toscana
Regione Toscana
Diritti Valori Innovazione Sostenibilità
collegamento sito usl 7 siena Servizio Sanitario
della
Toscana
LOADING TIME: 0.013 s.
XS SM MD LG XL

info@portaleagentifisici.it