Machine technical sheet


Brand: CHICAGO
Model: CP 893
Type: Straight, angle and pistol grip, impact or ratchet wrenches and screwdrivers
Built in: n.d.
Weight: 10.5 kg
Power supply: Pneumatic
Anti-vibration devices: Present
Source of the data: Acquisito sul campo da misuratore

Immagine rappresentante la tipologia
Declared values as set forth in the standard EN ISO 8662-7:1999
( x 1,5 Tightening bolts )
CONDITIONS MATERIAL ACCESSORY VALUE K(1) Note
Screwing, unscrewingBolts and nutsNOT ASSESSED6.2 m/s2
(1) Expanded uncertainty

Measurements in the field (Click to view the measurements in the field)

Reference person: Nicandro Mascio Unità Funzionale TAV e Grandi Opere - ASL 10 Firenze (nicandro.mascio@asf.toscana.it)
Location: Firenze on 20/11/2012
Features of the accessory: NOT ASSESSED
domDebug Array ( [id] => 1284 [data] => 2012-11-20 [referente] => 76 [dichiarazione_di_pubblicabilita] => Yes [luogo] => Firenze [comparto] => Costruzioni stradali e ferroviarie [numero_di_serie] => [accessorio_usato] => 1045 [t_lavoro_effettuato] => 2 [materiale_lavorato] => 190 [leq] => [note] => [foto1] => Yes [foto2] => No [foto3] => No [pressione] => 6.2 [frequenza] => 4400 [isValid] => Yes [referente2] => 76 [caratteristicheAccessorio] => [durata] => 60 [en_luogo] => [importato] => [caratteristicheLavoroEffettuato] => avvitatura bullonerie [caratteristicheMateriale] => [en_note] => [id_anagrafica_generale] => 21630 [owner_user] => 76 [stato] => valida [id_modello_strumento_di_misura] => 8 [id_sensore_strumento_di_misura] => 5 [id_adattatore_del_sensore] => 6 [accessorio] => NON INDICATO [en_accessorio] => NOT ASSESSED [materiale] => Bulloneria metallica [en_materiale] => Bolts and nuts [denominazione] => Unità Funzionale TAV e Grandi Opere - ASL 10 Firenze [nome_cognome] => Nicandro Mascio [tel] => 055 6933468 [email] => nicandro.mascio@asf.toscana.it [username] => nicandro [categoria] => 2 [lavoro] => Avvitatura, svitatura [en_lavoro] => Screwing, unscrewing [en_comparto] => Construction of roads and railways )
Conditions of measurement

Values related to the vibration worst case handle ​ ( Anterior )
A hx (Mean)
6.2 m/s2
A hy (Mean)
4.3 m/s2
A hz (Mean)
7.3 m/s2
A hv sum
10.5 m/s2
Standard deviation
0.1 m/s2
Standard deviation
0.1 m/s2
Standard deviation
0.1 m/s2
Standard deviation x 1,645:
0.16 m/s2
Mean
+ Standard deviation:
6.3 m/s2
Mean
+ Standard deviation:
4.4 m/s2
Mean
+ Standard deviation:
7.4 m/s2
A hv sum
+ (Dev. std. x 1,645):
10.7 m/s2
logo regione toscana
Regione Toscana
Diritti Valori Innovazione Sostenibilità
collegamento sito usl 7 siena Servizio Sanitario
della
Toscana
LOADING TIME: 0.041 s.
XS SM MD LG XL

info@portaleagentifisici.it