Machine technical sheet


Brand: HILTI
Model: DC 125 S
Type: Straight, vertical and angle grinders
Built in: n.d.
Weight: 1.8 kg
Power: 1.3 kW
Power supply: Electrical (220V-380V)
Anti-vibration devices: Absent
Last update: 23/07/2015
Source of the data: Acquisito sul campo da misuratore

Immagine rappresentante la tipologia
Declared values as set forth in the standard IEC EN 60745-2-3:2007
CONDITIONS MATERIAL ACCESSORY VALUE K(1) Note
NOT ASSESSEDNOT ASSESSEDNOT ASSESSED5.1 m/s21.5artificial grinding wheel. Grip type: vib-reduced
NOT ASSESSEDNOT ASSESSEDNOT ASSESSED10.3 m/s21.5artificial grinding wheel. Grip type: loop
(1) Expanded uncertainty

Measurements in the field (Click to view the measurements in the field)

Reference person: CPT Cagliari (cptcagliari@tiscali.it)
Location: Cagliari on 05/07/2007
Features of the accessory: Cutting disc
domDebug Array ( [id] => 288 [data] => 2007-07-05 [referente] => 11 [dichiarazione_di_pubblicabilita] => [luogo] => Cagliari [comparto] => Costruzioni edili [numero_di_serie] => [accessorio_usato] => 1049 [t_lavoro_effettuato] => 24 [materiale_lavorato] => 194 [leq] => [note] => [foto1] => [foto2] => [foto3] => [pressione] => [frequenza] => [isValid] => Yes [referente2] => 11 [caratteristicheAccessorio] => Disco diamantato [durata] => [en_luogo] => [importato] => Yes [caratteristicheLavoroEffettuato] => Taglio [caratteristicheMateriale] => Laterizio [en_note] => [id_anagrafica_generale] => 170 [owner_user] => 0 [stato] => [id_modello_strumento_di_misura] => 0 [id_sensore_strumento_di_misura] => 0 [id_adattatore_del_sensore] => 0 [accessorio] => Disco taglio [en_accessorio] => Cutting disc [materiale] => Laterizi [en_materiale] => Bricks (clay) [denominazione] => CPT Cagliari [nome_cognome] => [tel] => 0702084120 [email] => cptcagliari@tiscali.it [username] => cptcagliari [categoria] => 2 [lavoro] => Taglio [en_lavoro] => Cutting [en_comparto] => Building constructions )

Values related to the vibration worst case handle ​ ( Central )
A hx (Mean)
4.3 m/s2
A hy (Mean)
3.1 m/s2
A hz (Mean)
2 m/s2
A hv sum
5.7 m/s2
Standard deviation
0.18 m/s2
Standard deviation
0.16 m/s2
Standard deviation
0.03 m/s2
Standard deviation x 1,645:
0.37 m/s2
Mean
+ Standard deviation:
4.5 m/s2
Mean
+ Standard deviation:
3.3 m/s2
Mean
+ Standard deviation:
2 m/s2
A hv sum
+ (Dev. std. x 1,645):
6.1 m/s2
logo regione toscana
Regione Toscana
Diritti Valori Innovazione Sostenibilità
collegamento sito usl 7 siena Servizio Sanitario
della
Toscana
LOADING TIME: 0.021 s.
XS SM MD LG XL

info@portaleagentifisici.it