Machine technical sheet


Brand: HILTI
Model: TE 905 AVR
Type: Demolition hammers (light demolitions), road breakers and pick hammers (for rocks, buildings etc)
Built in: n.d.
Weight: 11.3 kg
Power: 1.6 kW
Power supply: Electrical (220V-380V)
Anti-vibration devices: Present
Source of the data: Acquisito sul campo da misuratore

Immagine rappresentante la tipologia
Declared values as set forth in the standard EN 50144-2-6
( x 2,0 Hammer drilling, Chiseling, Drilling without impact - x 1,5 Breaking concrete/masonry )
CONDITIONS MATERIAL ACCESSORY VALUE K(1) Note
NOT ASSESSEDNOT ASSESSEDNOT ASSESSED8 m/s2
(1) Expanded uncertainty

Measurements in the field (Click to view the measurements in the field)

Reference person: CPT Torino (seg@cpt.to.it)
Location: CESANA TO.SE (TO) on 23/05/2007
Features of the accessory: Pick, moil point
domDebug Array ( [id] => 428 [data] => 2007-05-23 [referente] => 14 [dichiarazione_di_pubblicabilita] => [luogo] => CESANA TO.SE (TO) [comparto] => Costruzioni edili [numero_di_serie] => [accessorio_usato] => 1057 [t_lavoro_effettuato] => 6 [materiale_lavorato] => 203 [leq] => 0 [note] => scheda 514 [foto1] => [foto2] => [foto3] => [pressione] => [frequenza] => [isValid] => Yes [referente2] => 14 [caratteristicheAccessorio] => punta (220x25 mm) [durata] => [en_luogo] => [importato] => Yes [caratteristicheLavoroEffettuato] => demolizione blocchi [caratteristicheMateriale] => pietra [en_note] => [id_anagrafica_generale] => 155 [owner_user] => 0 [stato] => [id_modello_strumento_di_misura] => 0 [id_sensore_strumento_di_misura] => 0 [id_adattatore_del_sensore] => 0 [accessorio] => Punta piramidale, punta conica [en_accessorio] => Pick, moil point [materiale] => Pietra [en_materiale] => Stone [denominazione] => CPT Torino [nome_cognome] => [tel] => 0113400311 [email] => seg@cpt.to.it [username] => cpttorino [categoria] => 2 [lavoro] => Demolizione [en_lavoro] => Demolition [en_comparto] => Building constructions )

Values related to the vibration worst case handle ​ ( Anterior )
A hx (Mean)
11.9 m/s2
A hy (Mean)
4.3 m/s2
A hz (Mean)
5.5 m/s2
A hv sum
13.8 m/s2
Standard deviation
0.25 m/s2
Standard deviation
0.3 m/s2
Standard deviation
0.31 m/s2
Standard deviation x 1,645:
0.68 m/s2
Mean
+ Standard deviation:
12.2 m/s2
Mean
+ Standard deviation:
4.6 m/s2
Mean
+ Standard deviation:
5.8 m/s2
A hv sum
+ (Dev. std. x 1,645):
14.5 m/s2
Reference person: CPT Perugia (info@cptperugia.it)
Location: TODI (PG) on 03/04/2007
Features of the accessory: Pick, moil point
domDebug Array ( [id] => 375 [data] => 2007-04-03 [referente] => 12 [dichiarazione_di_pubblicabilita] => [luogo] => TODI (PG) [comparto] => Costruzioni edili [numero_di_serie] => [accessorio_usato] => 1057 [t_lavoro_effettuato] => 6 [materiale_lavorato] => 203 [leq] => 0 [note] => [foto1] => [foto2] => [foto3] => [pressione] => [frequenza] => [isValid] => Yes [referente2] => 12 [caratteristicheAccessorio] => PUNTA [durata] => [en_luogo] => [importato] => Yes [caratteristicheLavoroEffettuato] => Demolizione [caratteristicheMateriale] => Roccia [en_note] => [id_anagrafica_generale] => 155 [owner_user] => 0 [stato] => [id_modello_strumento_di_misura] => 0 [id_sensore_strumento_di_misura] => 0 [id_adattatore_del_sensore] => 0 [accessorio] => Punta piramidale, punta conica [en_accessorio] => Pick, moil point [materiale] => Pietra [en_materiale] => Stone [denominazione] => CPT Perugia [nome_cognome] => [tel] => 0755059411 [email] => info@cptperugia.it [username] => cptperugia [categoria] => 2 [lavoro] => Demolizione [en_lavoro] => Demolition [en_comparto] => Building constructions )

Values related to the vibration worst case handle ​ ( Right )
A hx (Mean)
9.7 m/s2
A hy (Mean)
6 m/s2
A hz (Mean)
7.6 m/s2
A hv sum
13.7 m/s2
Standard deviation
1.3 m/s2
Standard deviation
0.72 m/s2
Standard deviation
1.24 m/s2
Standard deviation x 1,645:
1.74 m/s2
Mean
+ Standard deviation:
11 m/s2
Mean
+ Standard deviation:
6.7 m/s2
Mean
+ Standard deviation:
8.8 m/s2
A hv sum
+ (Dev. std. x 1,645):
15.4 m/s2
logo regione toscana
Regione Toscana
Diritti Valori Innovazione Sostenibilità
collegamento sito usl 7 siena Servizio Sanitario
della
Toscana