Machine technical sheet


Brand: BETA
Model: 1370 800
Type: Manual hammers
Built in: 2007
Weight: 0.8 kg
Power supply: Manual
Anti-vibration devices: Absent
Source of the data: Acquisito sul campo da misuratore

Immagine rappresentante la tipologia
Declared values as set forth in the standard EN ISO 5349-1: 2004 - EN ISO 5349-2: 2004
CONDITIONS MATERIAL ACCESSORY VALUE K(1) Note
No declared data
(1) Expanded uncertainty

Measurements in the field (Click to view the measurements in the field)

Reference person: Iole Pinto - Nicola Stacchini - Andrea Bogi AUSL Toscana Sud Est-LSP-Lab. Agenti Fisici (i.pinto@usl7.toscana.it)
Location: Poggibonsi (SI) on 24/05/2007
Features of the accessory: NOT ASSESSED
domDebug Array ( [id] => 1135 [data] => 2007-05-24 [referente] => 3 [dichiarazione_di_pubblicabilita] => [luogo] => Poggibonsi (SI) [comparto] => Autoveicoli e altri veicoli [numero_di_serie] => [accessorio_usato] => 1045 [t_lavoro_effettuato] => 19 [materiale_lavorato] => 190 [leq] => [note] => Martellate su pianale legno [foto1] => Yes [foto2] => [foto3] => [pressione] => [frequenza] => [isValid] => Yes [referente2] => 3 [caratteristicheAccessorio] => [durata] => 30 [en_luogo] => [importato] => [caratteristicheLavoroEffettuato] => [caratteristicheMateriale] => [en_note] => [id_anagrafica_generale] => 1350 [owner_user] => 0 [stato] => [id_modello_strumento_di_misura] => 0 [id_sensore_strumento_di_misura] => 0 [id_adattatore_del_sensore] => 0 [accessorio] => NON INDICATO [en_accessorio] => NOT ASSESSED [materiale] => Bulloneria metallica [en_materiale] => Bolts and nuts [denominazione] => AUSL Toscana Sud Est-LSP-Lab. Agenti Fisici [nome_cognome] => Iole Pinto - Nicola Stacchini - Andrea Bogi [tel] => 0577 536097 [email] => i.pinto@usl7.toscana.it [username] => iole [categoria] => 2 [lavoro] => Ribattitura [en_lavoro] => Clinching [en_comparto] => Motor vehicle industry )
Conditions of measurement

Values related to the vibration worst case handle ​ ( Central )
A hx (Mean)
4.5 m/s2
A hy (Mean)
3.1 m/s2
A hz (Mean)
2.4 m/s2
A hv sum
5.9 m/s2
Standard deviation
2.05 m/s2
Standard deviation
0.71 m/s2
Standard deviation
1.32 m/s2
Standard deviation x 1,645:
3.56 m/s2
Mean
+ Standard deviation:
6.6 m/s2
Mean
+ Standard deviation:
3.8 m/s2
Mean
+ Standard deviation:
3.7 m/s2
A hv sum
+ (Dev. std. x 1,645):
9.5 m/s2
logo regione toscana
Regione Toscana
Diritti Valori Innovazione Sostenibilità
collegamento sito usl 7 siena Servizio Sanitario
della
Toscana
LOADING TIME: 0.033 s.
XS SM MD LG XL