1) Does the production/service of your firm is such to place it among those firms whose working practices do not entail a relevant risk of exposure to Hand-Arm Vibration?
NO RELEVANT RISK
(it is not necessary to determine the A(8) for the operators)
END OF THE PROCEDURE
Identification of the machines used by the operators that transmit, according to the judgement of the evaluator, the highest vibration to the hand-arm system
MACHINERY type, brand, model |
WORKING PRACTICE e.g. sheet metal drilling, concrete demolishing... |
Select to assess the risk (1) | Click to remove |
---|
WORKING CONDITION
Type, Brand, Model
|
Vibration level ahv m/s2 |
TIME OF EXPOSURE
in the recurring working day at maximum risk [hours]
|
PARTIAL DAILY EXPOSURE A(8) |
---|
Selected line: | |
Selected type ID: |
Total time | hours | |
A(8) | m/s2 |
By searching in the PAF database |
By manually entering the data |
Type | |
Brand | |
Model | |
Working practice |
Type | |
Brand | |
Model | |
Working practice |
Vibration value [m/s2] | Where is it located? | |
Time of exposure in the recurring working day at maximum risk in hours | ||
Partial daily exposure A(8) | m/s2 |
Measured vibration value [m/s2] | See measurement protocols | |
Uncertainty [m/s2] | ||
Time of exposure in the recurring working day at maximum risk in hours | ||
Partial daily exposure A(8) | m/s2 |
Type of machinery: | |
Reference standard: |
Declared vibration value [m/s2] | X | |
Multiplicative coefficient | = |
Declared vibration value [m/s2] | + | |
Uncertainty (according to the manual) | = |
Resulting vibration level | m/s2 | |
Time of exposure in the recurring working day at maximum risk in hours | ||
Partial daily exposure A(8) | m/s2 |
Grinders (straight/axial, vertical, angle) HILTI AG 125 SE |
Sheet metal cutting | ||
Drills (straight, gun, angle) BOSH GSE 657 |
Concrete drilling |